DC Resistivity and IP

TRANSMITTERS

Huntec Mark II 7500 Transmitter

Power Input: 120/208 V AC ± 10%, 3 phase 400 Hz.
Power Output: 100 – 3250 V DC in 10 ste½s, 16 Amps maximum, 7.5 Kilowatt transmitter.
Input Voltage Meter: 0-150 V AC.
Temperature Range: -30° F to +120° F.


Pheonix IPT-1 Transmitter

Power Input: 80 – 90V AC, 3 phase 400 Hz.
Power Output: 75 – 1200V in 5 steps, 3 mA – 10 Amps.


Walcer Tx 9000 Transmitter with Generator

Power Input: 125V line to neutral, 400 Hz / 3 phase, powered by MG-12.
Power Output: 100 – 3200V in 10 steps, 0.00 – 20.00 Amps, tested to 9.25 kVA.
Switching: 1 sec, 2 sec, 4 sec, 8 sec.
Metering: LED for line voltage and output current.


GDD 3600 TxII Transmitter

Operating Temperature: -40°C to 65°C.
Time Base: 2 s ON+, 2 s OFF, 2 s ONDC, 0.5, 1, 2, 4, 8 or 16 s.
Rated Output Voltage: 150V to 2400V. Up to 4800V in a master/slave configuration.


VIP 4000 Transmitter

Operating Temperature: -40 to +50°C.
Frequency Option: 0.0625Hz to 4Hz by factors of 2.
Resolution/Accuracy: 1 mA / 1%.


Zonge GGT-10 Transmitter

Operating Temperature: -40°C to +55°C.
Maximum input: 10KVA @ 30°C.
Output voltage range: 50 to 1000V.
Output current range: 0.2 to 20A.
Current stability: ±0.2%.
Frequency range: DC to 8 kHz.

RECEIVERS

No IP receivers available at this time.